Bionet Patient Monitors BM3
-
NG # 006406-HW-BIONET-006
Manufactured by:
Specification
Hardware Specifications Dimension (W x H x D)
& WeightBM3 240 x 237 x 176 / Approx 3.1 kg Display / Resolution BM3 8” / 800 X 600 Parameters BM3 ECG, Heart Rate, Respiration Rate, SpO2,
Pulse Rate, Systolic BP, Diastolic BP, Mean BP,
ETCO2, FiCO2, Airway Respiration Rate, 1CH-TempTrace BM3 4 Waveforms : 2*ECG, SpO2, RR or ETCO2 Indicators Categorized Visual alarm lamp (3 priority levels)
SpO2 pulse pitch tone, Battery status,
External power LEDInterfaces DC input connector : 18 VDC, 2.8 A
LAN port for transferring data
Nurse call system connection
HDMI output connector
USB connectorBattery Rechargeable BM3 : 3250 mAh
(or optional 6500 mAh) Data Storage 168 hrs (saving interval 1 min) Water Resistance IEC 60529:2013 Degress of protection provided
by enclosures, IPX2ECG ECG lead & Waveforms BM3 3-lead : 1 channel I, II, III
5-lead : 1 / 2 channels I, II, III, aVR, aVL, aVF, VHeart Rate Range Adult / Pediatric : 30 ~ 300 bpm
Neonate : 30 ~ 350 bpmHeart Rate Accuracy ± 1 bpm or ± 1 %, whichever is greater Sweep Speed 6.25, 12.5, 25, 50 mm/sec Filter Diagnosis : 0.05 ~ 150 Hz
Monitoring : 0.5 ~ 40 Hz
Moderate : 0.5 ~ 25 Hz
Maximum : 5 ~ 25 HzST Segment
Detection Range-2.0 ~ 2.0 mV Arrhythmia Analysis BM3 : Asystole, VTach, VFib Pacemaker Detection
ModeIndicator on waveform display Protection Against electrosurgical interference and defibrillation Respiration Performance Method Thoracic impedance Channel Selection BM3 : RA-LL Measurement Range 5 ~ 120 breaths per minute Accuracy ±1 breath per minute Apnea Alarm Yes Temperature Performance Measurement Range 0 ~ 50 ℃ (32 ~ 122 ℉) Accuracy 25 ~ 50 ℃ : ± 0.1 ℃ 0 ℃ to the less than 25 ℃ : ± 0.2 ℃ Compatibility 98ME04GA603 temperature probes Temperature Range Operating : 5 ~ 40 °C (41 ~ 104 °F)
Storage : –20 ~ 60 °C (–4 ~ 140 °F)Channels 1CH SpO2 Saturation Range 0 ~ 100 % Saturation Accuracy 70 ~ 100 % : ± 2 digits
0 ~ 69 % : unspecifiedPulse Rate Range 30 ~ 254 bpm Pulse Rate Accuracy ± 2 bpm NIBP Method Oscillometric Operation Mode Manual / Automatic / Continuous Measurement Range
(Adult)Systolic : 40 ~ 260 mmHg
MAP : 26 ~ 220 mmHg
Diastolic : 20 ~ 200 mmHgAccuracy Mean error : less than ± 5 mmHg
Standard deviation : less than 8 mmHg
Meets accuracy requirements
of ANSI/AAMI SP10:2002 ETCO2 (Main / Sidestream) Measurement Range 0 ~ 150 mmHg, 0 ~ 19 % Accuracy 0 ~ 40 mmHg ± 2 mmHg
41 ~ 70 mmHg ± 5 % of reading
71 ~ 100 mmHg ± 8 % of reading
101 ~ 150 mmHg ± 10 % of readingRespiration Rate 2 ~ 150 breaths per minute Respiration Accuracy ± 1 breath per minute
Description
The BM3 delivers compact and precise monitoring solutions with an 8-inch touch screen, 4 waveforms, and a user-friendly pop-up trend menu for low to mid acuity recovery applications.