89/2, West Panthapath,Dhaka
APPLICATIONS
The needs for accurate low resistancemeasurement are well
known and verydiverse. They range through receiving, inspection of components
toground bonding and welded joints.Typical end users include utilities,telecom,
railroads, aviation, manufacturing facilities, and process controlplants.
Applications include, but arenot limited to, making dc resistancemeasurements
for:
• Switch and contact breaker resistance
• Busbar and cable joints
• Aircraft frame bonds and static
control circuits
• Integrity of welded joints
• Intercell strap connections on
battery systems up to 600 V peak
• Quality control of resistivecom ponents
• Small transformer and motor winding resistance
• Rail and pipe bonds
• Metal alloys welds and fuse resistance
• Graphite electrodes and other composites
• Wire and cable resistance
• Transmitter aerial and lightning conductor bonding
SPECIFICATIONS
Test Current Accuracy:
±10%
Output Current
Stability
Better than 10 ppm per second on at test currents of 10 mA
or less Better than 100 ppm per second at currents above 10 mA
Voltmeter Input
Impedance: greater than 200 kΩ
Hum rejection:
less than 1% + 20 digits additional error with 100 mV rms 50/60 Hz on potential
leads. If this level is exceeded, a warning will illuminate on the front panel.
Measurement speed:
less than 3s for foward, reverse measurement and to display average.
Display
Measurement: 4-1/2 digit seven segment LED Range and Safety:
LED indication
Battery
Standard capacity: 7 Ah NiMH rechargeable battery supplied
with instrument Recharge: via external charger supplied from 115/230 V 50/60 Hz
or from 12 V car battery Life: typically 1000 x 10 A test.
Battery charging
Standard Charge: 14 hrs
Fast Charge: 4 hrs to 90 % capacity at
68o F (20o C)
Charging temperature
Standard charge: 32o F to 113o F
(0o C to +45oC)
Fast charge: 50o to 113o F
(+10o to +45o C)
Temperature Range
Operation
41o to 113o F (+5o to +45o C) at full
14o to 122o F (-10o to +50o C) at reduced accuracy Calibration
temperature
68o F (20 o C)
Temperature Coefficient
<0.006% per oF over range 41o to
104o F
<0.01% per oC over range 5o to 40 oC
Storage
-4o to 158o F (-20o to +70o C)
Humidity (max):
90% RH @ 104oF
(40oC) non-condensing
Altitude (max):
6562 ft (2000 m) to full
safety specifications
Safety: in
accordance with EN61010-1
600 V Category III
EMC: meets
EN50081-1 and EN50082-1
(1992)
Dimensions: 8.6 x
4 x 9.5 in.
(220 x 100 x 237 mm)
Weight: 5.6 lb
(2.5 kg) including battery module