Performance Specifications and Operating Conditions
Test Method :
Data Trending
CELScan® Frequency Response Analysis. Completely
non-intrusive.
Available but not required for measurement and detection of
battery
health degradation. (Battery health is determined from a
single
measurement).
Amp-Hour Capacity Range
for Batteries Under Test
5 Ah to 2,000 Ah, Specified Performance Range
1 Ah to 9,999 Ah Operating Range
Amp-hour measurement capabilities depend upon whether or not
the battery
impedance is within the measurement range of the device.
Typically, the
larger a battery’s Ah capacity, the lower its impedance.
Measures Battery on Float Yes – (battery must be fully
charged and at equilibrium)
Measures Batteries at
Open-Circuit Yes – (battery must be fully charged and at equilibrium)
Impedance
Measurement Range 50 µΩ to 2.8 Ω
Resolution 0.001 mOhms for all measurable impedance values
Accuracy ± 1.0 % (for Impedance > 1 mΩ to 1Ω)
± 1.0 % (for Impedance > 100 µΩ to 1 mΩ)
Accuracy Traceability Through NIST traceable standards
Repeatability ± 1.0 % (for Impedance from 100 µΩ to 2.8 Ω)
Voltage
Range 0 to 17 VDC
Resolution (Display) 10 mV
Accuracy ± 0.5 %
Accuracy Traceability Through NIST traceable standards
Repeatability ± 0.5 %