RKI Beacon 3200 Controller

RKI Beacon 3200 Controller

RKI
TF: 002751-HW-RKI-051
Overview

The all new Beacon 3200 is a versatile, advanced fixed system controller for up to 32 points of gas detection. It is capable of controlling up to 32 separate gas detection sensors. Sensor types can be direct connect, 4-20 mA (2 or 3 wire) or Modbus transmitters. The Beacon 3200 can be powered by either 115 VAC, 220 VAC, or 24 VDC. A battery backup option is available and receives its trickle charge from the Beacon 3200. It is simple to operate and comes complete with a wall mount installation kit.

Physical

DimensionsHeight: 16” (40.64 cm) x Width: 13.75” (34.93 cm) x Depth: 6.5” (16.51 cm)
EnclosureNEMA 4X fiberglass / polyester with lexan window for indoor and outdoor locations.
Conduit Connection3/4” NPT conduit hubs, 9 provided, for sensor, power, & relay wiring.
Wiring TerminationScrew type terminal block, 14 gauge max.
Power115 VAC, 220 VAC, or 24 VDC nominal. Battery backup option available.
Optional AccessoriesStrobe light, and battery backup assembly.
ControlsTouchscreen, reset button.

 

Environmental
Operating Temperature-40°F to 122°F (-40°C to 50°C)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Relative Humidity0 – 80% RH
Enclosure RatingNEMA 4X enclosure, chemical and weather resistant. Suitable for indoor and outdoor installations.

 

Inputs

Direct Wired Sensors

LEL, Oxygen, Carbon Dioxide, and various toxic gas sensors.

 

Amplifier not required for less than 500 feet.

4-20 mAAccepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI/Riken sensors are available with
4-20 mA signals. Wiring distances up to 8,000 feet. Compatible with: S2 Series, M2A, T2A, T3A, VOC Pro, Air Alert, GD-70D, and others.
ModbusAccepts M2A, T3A, VOC Pro, Air Alert.
Sampling MethodsDiffusion and sample draw heads available.

 

Outputs

RelaysFour common Form C (C, NO, NC) relays (Fail, Alarm-1, Alarm-2, Alarm-3). Common relays may optionally be assigned to function as additional channel alarm relays, providing for up to three alarm relays per channel. Additional relays available on optional relay cards. 115/220VAC, 6A, or 30VDC contact relay.
4-20 mASignal output, 4-20 mA (maximum load impedance 500 ohms output), per channel.
RS-485 ModbusModbus format RS-485 serial output of all channel data, including gas reading and alarm status.
EthernetModbus TCP/IP output of all channel data, including gas readings and alarm status.
Display7” Color LCD display of all 32 channels.
Audible

Built-in audible alarm, 90 dB, mounted on enclosure.

 

Coded output: pulsing = gas alarm, steady = fail

Visual
  1. Touchscreen indications for each channel reading
    • Alarm 1 = yellow • Alarm 2 = orange • Alarm 3 = red • Fail = red
  2. An optional 24 VDC NEMA 4X strobe mounted to top of case.
DataloggingIncluded as standard for all 32 channels. Records to SD card.

The large 7” color LCD touchscreen can access control and maintenance functions as well as display all 32 channels. The Beacon 3200 is housed in a NEMA 4X rated case for a weather tight seal. This case design complies with lockout / tag out standards and can be fully secured. An external reset switch allows alarms to be silenced from outside the controller housing. Nine bottom wiring hubs allow for easy wiring.